Electrical position: temporary power inspections current; one extension lead with damaged outer insulation removed from service on Level 2; plasterboard stored close to a distribution board has been relocated. Agreed to reinforce pre-use equipment checks and maintain clear access to all distribution boards.
1.1.2
PPE compliance generally good; three operatives recorded without safety glasses in the internal cutting area. Observations continue to be recorded by subcontractor and category, with escalation through the subcontractor management meeting if patterns repeat.
1.1.3
Upcoming high-risk activities: steel installation (north side), roof membrane work commencing Tuesday, and mechanical plant lifting operations Wednesday. Agreed the delivery route will be closed and vehicles redirected via the south gate between 10:00 and 13:00; lift plan to be approved once the revised traffic arrangement is attached, and a pre-lift briefing held.